The Acid-Resistant CentriVap Vacuum Concentrator rapidly concentrates multiple small samples containing chemicals such as 0.1 to 1% TFA, hydrochloric acid, acetic acid, hydrobromic acid, ammonium hydroxide and sodium hydroxide
Components in the vapor path are constructed of corrosion-resistant materials for long life
Brushed stainless steel and glacier white, epoxy-coated steel exterior with blue accents
Glass lid
Lid latch with safety sensor
Phenol-free lid gasket
PTFE-coated aluminum chamber with Hastelloy shaft
300-watt heater
Microprocessor-controlled programming for run time from 1 to 999 minutes, heat from OFF to HI (100 C) in one degree increments, and heat time from 1 to 999 minutes. Memory stores 1 to 9 programs
LCD for display of program number, actual and set point temperature, heater time remaining, and run time remaining
Control panel with RUN/STOP button, PREHEAT button, set point SELECT button, increase/decrease buttons, and 3 Quick-Start buttons
Centrifugal motion is provided by a brushless motor capable of achieving up to 1725 rpm
Quick-Stop System to stop vacuum pump, open valve to bleed air into the chamber and stop the rotor within seconds after time expires or RUN/STOP button is pressed
Automatic vacuum release valve
Built-in vacuum delay allows rotor to achieve speed before applying vacuum
Audible alarm to signal completion of set point run time
1/2" OD aluminum hose fitting for connection to vacuum tubing. Vacuum pump is not included.
Vacuum port with quick disconnect fitting for 1/4" ID tubing
115 volt models have a 115 volt electrical receptacle on the back to connect accessory vacuum pump to the system
230 volt models have a reverse IEC electrical receptacle on the back to connect accessory vacuum pump to the system
115 volt models have a 6.5-foot, 3-wire cord with NEMA 5-15 plug
230 volt models have an 8-foot cord with NEMA 6-15 plug
Disclaimer : No part of this site constitute medical advice or nor it replaces any advice provided by healthcare adviser. We urge buyer to take advice from the designated healthcare adviser about usage of any product here or if it is suitable for the buyer. This site takes no responsibility of the consequences arising out of the usage of any product from this site. By buying products from this site, buyer agree that buyer has the knowledge of the usage of the product. All warranties implied or explicitly mentioned here are responsibility of the manufacturer of the product. We are not able to accept any insurance or Medicaid or Medical for any purchase. Our apologies for that inconvenience.